100 Watt H.P.S.
Dusk-to-Dawn Security Light
© 2008 HeathCo LLC 598-1054-04
Installation Instructions With Two Piece Arm
READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through
conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of
the system.
Lens/Reflector
Assembly
Mounting
Arm
Lag Screw (4)
Flat Washer (10)
Mounting
Bracket
Photocontrol
Ground
Screw
1. Select a location on a flat wall with structurally sound wood and
from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should
be at least one inch thick to safely secure the fixture.
2. Slide the curved section of the mounting arm into the mounting
bracket. Tighten the bolts on the mounting bracket evenly.
3. Using the mounting arm and bracket as a guide mark four mount-
ing holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the
lag screws.
4. Mount the arm and bracket using four lag screws and washers
provided.
5. Place a ring of silicone caulk around mounting arm (see illustra-
tion). Slide the straight section of the mounting arm on to the
curved section aligning the predrilled holes.
6. Secure the two sections with two bolts, nuts and four washers
provided. Place silicone caulk on top of the bolts and washers
to prevent water from entering.
7. Thread your outdoor cable or flexible conduit through the mount-
ing arm.
8. Loosely connect the mounting strap to the fixture using two bolts
provided.
9. Slide the fixture on to the mounting arm until the fixture comes
to a stop. Secure the fixture to the mounting arm by tightening
the two mounting strap bolts.
10. Connect thexture wires to the service wires using the wire nuts
provided (black to black and white to white). Push the connec-
tions as far as possible into the straight arm.
11. This fixture must be grounded. Connect the service ground under
the head of the green ground screw and secure to the mounting
strap.
12. Install the lens/reflector assembly with two screws and washers
provided.
13. Screw in the 100 watt H.P. Sodium type S54 lamp provided.
14. Loosen the screw in the center of the photocontrol socket two
turns. Twist the socket so that the arrow points north. Note: There
is a stop to prevent the socket from turning all the way around. If
you have trouble turning the socket, try turning it the other direc-
tion. Retighten the screw in the center of the socket.
Mounting Strap
Silicone
Caulk
15. Align the photocontrol (it will only plug-in one way). Plug it in
and twist clockwise until it stops.
To test operation during daylight, cover the photocontrol with a
small box. Turn on the power. Not all photocontrols are alike. Some
may have a time delay of a few minutes, others will turn on as soon
as power is applied. The light will take up to ten minutes to reach
full brightness. Uncover the photocontrol and your unit will operate
automatically—on at dusk, off at dawn.
Model SL-5666
WARNING: Turn power off at the circuit breaker or
fuse.
Lamp in Fixture Contains Mercury. Dispose According
to Local, State, or Federal Laws.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Model SL-5666

100 Watt H.P.S.Dusk-to-Dawn Security Light© 2008 HeathCo LLC 598-1054-04Installation Instructions With Two Piece ArmREAD ALL INSTRUCTIONS CAREFULLY B

Page 2

10598-1054-04Mode d’installation du modèle sans brasLIRE SOIGNEUSEMENT LES DIRECTIVES AVANT D’ENTREPRENDRE L’INSTALLATION.NOTE : Le câblage doit être

Page 3

11598-1054-04Douille d’ampoule Ballast Igniteur Rouge Rouge Rouge Noir Noir Bleu Bleu Blanc Blanc Blanc Noir Blanc Noir Douille de la cellule photo-é

Page 4 - TECHNICAL SERVICE

12598-1054-04GARANTIE LIMITÉE DE 5 ANSIl s’agit d’une « Garantie limitée » qui vous confère des droits juridiques spécifiques. Vous pouvez également jo

Page 5 - Modelo SL-5666

2598-1054-04Cover PlateMounting PlateLag Screw (3)Flat Washer (9)PhotocontrolGround Screw1. Select a location on a flat wall with structurally sound w

Page 6

3598-1054-04Lamp Socket Photocell Socket Ballast Ignitor Red Red Red Black Black Blue Blue White White White Black White Black 120V ACInputBallast As

Page 7

4598-1054-04FIVE YEAR LIMITED WARRANTYThis is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary fro

Page 8 - SERVICIO TÉCNICO

5598-1054-04 Lámpara de Seguridad de Sodio deAlta Presión (H.P.S.) del Crepúsculoal Amanecer de 100 VatiosInstrucciones para instalación con brazo de

Page 9 - Luminaire de sécurité

6598-1054-041. Seleccione una ubicación en una pared plana con una madera estructuralmente firme y entre 3 a 7.6 m (10 a 25 pies) del suelo. La madera

Page 10 - 598-1054-04

7598-1054-04Zócalo de la lámpara (boquilla) Estabilizador Encendedor Rojo Rojo Rojo Negro Negro Azul Azul Blanco Blanco Blanco Negro Blanco Negro Zóc

Page 11

8598-1054-04GARANTÍA LIMITADA A 5 AÑOSEsta es una “Garantía Limitada” que le da a Ud. derechos legales específicos. Usted puede también tener otros der

Page 12 - SERVICE TECHNIQUE

9598-1054-04Luminaire de sécuritécrépuscule-aurore au sodiumhaute pression (SHP de 100 W)Mode d’installation du modèle avec bras en deux piècesLIRE SO

Comments to this Manuals

No comments