Heath Zenith SL-5210 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
595-4991-07
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating
vents and air conditioners. These heat sources could
cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting daylight may
trigger the shut-off feature. Do not point other lights at the
sensor.
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
SPECIFICATIONS
Range . . . . . . . . . . . . . . . Up to 60 feet (varies with surround-
ing temperature).
Sensing Angle . . . . . . . . . Up to 110°
Electrical Load . . . . . . . . . Up to 500 Watts Maximum, Incan-
descent
Power Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . . . . . . TEST, AUTO and MANUAL OVER-
RIDE
Time Delay . . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and
to change specifications at any time without incurring any
obligation to incorporate new features in products previously
sold.
The detector is less sensitive to motion directly towards it and
more sensitive to across motion.
Aim Sensor Down
for Short Coverage
Aim Sensor Higher
for Long Coverage
Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area.
Adjust the SENSITIVITY as
needed. Too much sensitivity may
increase false triggering.
Set the amount of TIME you want
the lights to stay on after motion is
detected (1, 5, or 10 minutes).
Least Sensitive Most Sensitive
Sensor
Motion
Motion
ON-TIME
10 5 1 TEST
MIN MAX
SENS
Bottom of Sensor
60 ft.
5 ft.
110°
Maximum Range Maximum
Coverage Angle
NOTE: Sensor has a 1
1
/
2
minute warm up period before
it will detect motion. When first turned on or when
switching modes, wait 1
1
/
2
minutes.
Turn the SENSITIVITY (SENS) control to the mid position
and the ON-TIME control to the TEST position.
Page view 2
1 2 3 4 5 6 7 8 ... 11 12

Comments to this Manuals

No comments